## **Quick answer**

 A split case pump is a [centrifugal pump](https://www.defucc.com/wp-content/uploads/wp-mfa-exports/post/what-is-a-sewage-centrifugal-pump.md) with a casing that separates for easier access to internal components. Many models use a double-suction impeller to handle high flow efficiently. They are commonly used in water systems that require high flow, including municipal and industrial applications.

## **What Is a Split Case Pump?**

A split case pump is a centrifugal pump whose casing separates along a parting plane, allowing the pump to be opened without removing the entire casing from the installation.

Split case and double suction don’t mean the same thing. Split case describes how the casing is constructed. Double suction means liquid enters the impeller from both sides. Many large single-stage split case pumps combine the two features.

One example is DEFUCC’s [TPOW split case double suction pump](https://www.defucc.com/product/tpow-split-case-double-suction-pump/). It uses a single-stage, double-suction centrifugal design, with liquid entering the impeller from both sides.

## **How Does a Split Case Pump Work?**

The split case pump working principle follows the centrifugal process, but a double-suction design divides the incoming flow between two sides of the impeller.

As the impeller rotates, it adds energy to the liquid and moves it outward into the volute. The casing then directs the flow toward the discharge.

Because the incoming flow is shared between two impeller eyes, the full suction flow doesn’t have to pass through one inlet. That two-sided entry is what distinguishes the double-suction arrangement from a conventional single-suction design.

## **Why Does the Casing Split Horizontally?**

In a typical horizontal split case pump, the casing separates along a plane parallel to the shaft. Maintenance crews can remove the upper half to reach the pump internals from above.

On designs with the suction and discharge connections contained in the lower half, the main pipework can stay connected during this work. Our TPOW model uses this type of split-volute construction, allowing access to the pump internals without dismantling the main piping.

## **How Do Single-Stage and Multistage Split Case Pumps Differ?**

One impeller is used by a single-stage pump to develop head. Duties that demand a large volume of water at the head developed by a single stage typically use this configuration.

A multistage design places multiple impellers in series. Additional head is gained by the liquid as it passes through each stage, enabling the pump to reach higher pressures than comparable single-stage designs.

As such, stage count largely changes how much head can be developed by the pump, rather than what makes the casing a split-case design.

## **Can Split Case Pumps Be Horizontal or Vertical?**

Yes, although “horizontal” and “vertical” can refer to different aspects of a pump’s construction.

A pump’s shaft can be mounted horizontally or vertically. Separately, the casing can be classified by its split plane. An axially split casing has a joint parallel to the shaft, for example.

This distinction matters when space is limited. A vertical mounting arrangement can reduce the amount of floor area required. DEFUCC’s TPOW can be mounted horizontally or vertically according to the working conditions.

## **What Are the Advantages of a Split Case Pump?**

Double-suction split case pumps are particularly useful when a system needs to move a large volume of water. Dividing the incoming flow between two impeller eyes reduces the amount entering through each side.

This arrangement can also reduce NPSHr compared with a comparable single-suction design. The opposing flow into the two sides of a symmetrical impeller helps balance axial thrust.

When selected for its intended operating point, a split case pump can also operate efficiently at high flow rates. This makes the design useful where a system needs to move large volumes of water continuously.

## **What Are the Limitations of Split Case Pumps?**

A horizontal split case pump generally takes up more floor space than a compact end-suction pump designed for a smaller duty.

The equipment and installation can cost more as well because the construction is larger and more complex. For a lower-flow application, an end-suction pump may meet the duty with less equipment and floor space.

## **Where Are Split Case Pumps Used?**

Split case pump applications commonly involve moving large volumes of water. Municipal systems use them for water supply and distribution. Industrial facilities use them for water transfer and cooling circulation.

![](https://www.defucc.com/wp-content/uploads/2026/10/d567476f-8a03-472b-8aa9-3c374f069867-1.jpg)

They are also found in drainage and irrigation systems. Power plants can use split case pumps for circulating or cooling water duties.

Fire protection is another important application. DEFUCC’s [ESF UL split case fire fight pump](https://www.defucc.com/product/esf-ul-split-case-fire-fight-pump/) is designed with UL approval and handles clear water at flow rates up to 2,000 GPM.

For high-volume water-transfer duties, DEFUCC’s TPOW range reaches capacities up to 16,236 m³/h and heads up to 300 m.

## **How Do You Select a Split Case Pump?**

The required duty determines the size of the pump, but the installation also needs to provide adequate suction conditions for the selected model. Check the available NPSH against its NPSHr at the intended operating point.

Space can influence the configuration. A horizontal unit needs room for its baseplate and maintenance access, whereas vertical mounting may suit a site with limited floor area.

For fire protection, check the exact approval or standard required by the project rather than assuming every split case model carries the same listing. The selected pump still has to satisfy both the hydraulic duty and the requirements of the installation.

## **FAQ**

### **Are All Split Case Pumps Double Suction?**

No. Split case describes the casing construction. Double suction describes a design in which liquid enters both sides of the impeller.

### **Why Are Split Case Pumps Used for High Flow?**

A double-suction design divides incoming flow between two impeller eyes. This allows high flow without routing the full suction flow through one impeller inlet.

[Get Free Quote](https://www.defucc.com/wp-content/uploads/wp-mfa-exports/page/contact.md)



Welcome to Our Blog!
Professional Dewatering Pump Manufacturer

 Written by the Engineering & Solutions Team at WENZHOU DEFU MACHINERY CO., LTD. Backed by 3 manufacturing bases and over 10 years of expertise as a leading dewatering pump manufacturer, our team is dedicated to sharing practical dewatering pump insights and engineered fluid handling solutions for global projects.

 [ Contact Us → ](https://www.defucc.com/wp-content/uploads/wp-mfa-exports/page/contact.md) 

 ![WENZHOU DEFU MACHINERY CO., LTD. - Dewatering Pump Manufacturer](https://defucc.b-cdn.net/wp-content/uploads/2025/06/2-1-1--768x534.jpg)