{"id":3172,"date":"2026-10-21T10:11:33","date_gmt":"2026-10-21T02:11:33","guid":{"rendered":"https:\/\/www.defucc.com\/?p=3172"},"modified":"2026-10-29T11:41:55","modified_gmt":"2026-10-29T03:41:55","slug":"tunnel-dewatering-pump-staged-drainage","status":"publish","type":"post","link":"https:\/\/www.defucc.com\/es\/blog\/mine-dewatering\/tunnel-dewatering-pump-staged-drainage\/","title":{"rendered":"Tunnel Dewatering Pumps: How to Plan Staged Drainage"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Respuesta r\u00e1pida<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For effective tunnel dewatering, the inflow must be collected from the source, transferred using planned lift stations, and ensure that the pump capacity is adequate enough to cope with varying depths of excavation and drainage demands. The dewatering system must ensure that there is a safe working face and clear access paths.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The MP Series vacuum-assisted dry-priming <a href=\"https:\/\/www.defucc.com\/es\/blog\/buying-guide\/slurry-pump-vs-dewatering-pump\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/buying-guide\/slurry-pump-vs-dewatering-pump\/\" rel=\"noreferrer noopener\">bomba de deshidrataci\u00f3n de lodos<\/a> might be appropriate for situations with fluctuating water levels and suspended solids, based on its operational limitations. The pump curve, ability to handle solids, suction capability, and installation requirements must be compared against the duty calculations at each drainage level before selecting DEFU.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Water Inflow Points<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Determine where water is entering the tunnel prior to locating pumps; seepage through the face, joints, probe holes, groundwater, washdown, and surface water all act differently. Identify known entry points on the tunnel layout plan and record changes according to chainage, shift, rainfall, and excavation activity to ensure that a leak is recognized rather than every increase being considered normal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Source control for tunnel construction dewatering may help to lower the amount of water reaching the drain network, but all drainage, grouting, and groundwater lowering techniques must conform to the geotechnical design of the project. Unexpected drawdown may impact the surrounding soil and utilities, while water containing sediment will require treatment prior to discharge.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Staged Lifting and Pump Placement<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Use gravity channels where practical to guide water toward sumps, then place pumps at planned low points or intermediate lift stations as the tunnel advances. Each stage should have a defined catchment, access for inspection, a discharge connection, and a way to isolate or service equipment without blocking the active work area.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-1200x628.webp\" alt=\"Tunnel dewatering diagram showing groundwater seepage, gravity drainage channels, collection sumps, staged pump stations, and a discharge pipeline.\" class=\"wp-image-3173\" srcset=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-1200x628.webp 1200w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-500x262.webp 500w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-300x157.webp 300w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-768x402.webp 768w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-18x9.webp 18w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-143x75.webp 143w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-484x253.webp 484w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-4-800x419.webp 800w\" sizes=\"auto, (max-width:767px) 484px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For tunnel dewatering, calculate required flow at the <a href=\"https:\/\/www.defucc.com\/es\/blog\/buying-guide\/total-dynamic-head-dewatering-pump\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/buying-guide\/total-dynamic-head-dewatering-pump\/\" rel=\"noreferrer noopener\">cabezal din\u00e1mico total<\/a> for each stage, including elevation gain and friction through hoses, pipes, bends, and valves. Do not add pump nameplate maximum-flow figures together and assume they represent delivered capacity; check the operating point on the curve and verify that downstream stages can accept the combined inflow.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Stage planning check<\/strong><\/th><th><strong>What to verify on site<\/strong><\/th><th><strong>Why it matters<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Collection<\/td><td>Channel slope, sump volume, and sediment trap access<\/td><td>Reduces standing water and limits solids entering the pump<\/td><\/tr><tr><td>Lift point<\/td><td>Elevation, duty point, service clearance, and lifting method<\/td><td>Confirms the pump can deliver the required flow safely<\/td><\/tr><tr><td>Transfer route<\/td><td>Pipe or hose rating, restraints, joints, and discharge destination<\/td><td>Prevents leaks, movement, and unplanned backflow<\/td><\/tr><tr><td>Handover<\/td><td>Test result, alarms, responsible operator, and backup plan<\/td><td>Maintains a consistent drainage setup across shift changes.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Sand and Abrasion<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tunnel water can carry rock fragments, sand, grout residue, and fine sediment, especially after excavation or face treatment. Confirm the largest expected particle, solids concentration, and whether the flow is abrasive or contains stringy debris; pump type, impeller passage, casing material, and wear parts must suit those conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A sump that collects too much sediment can bury a strainer or reduce usable storage before the pump appears to fail. If flow drops, check water level, suction leakage, strainer blockage, impeller wear, and discharge restrictions in that order, then record the cause and corrective action so recurring issues can be traced to a location or activity.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-1200x628.webp\" alt=\"Tunnel dewatering pump intake diagram showing rock fragments, sand, fine sediment, sediment accumulation, and a discharge pipeline.\" class=\"wp-image-3175\" srcset=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-1200x628.webp 1200w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-500x262.webp 500w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-300x157.webp 300w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-768x402.webp 768w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-18x9.webp 18w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-143x75.webp 143w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-484x253.webp 484w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image5-3-800x418.webp 800w\" sizes=\"auto, (max-width:767px) 484px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Space Constraints<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Limited space for personnel, vehicles, ventilation systems, cables, and material handling makes it essential to coordinate pump placement with the excavation sequence before water accumulation disrupts tunnel operations. Keep pumps and hoses outside escape paths and equipment turning areas, and preserve safe access to isolation points, lifting devices, and electrical controls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before installation, verify the suction lift, hose diameter, bends, and connection seals, as excessive suction resistance or air leaks can cause a pump to lose prime when operating farther from the sump, even if it performs well during surface testing. Where diesel equipment is considered underground, the site\u2019s ventilation, exhaust, fire, and fuel-control requirements must be assessed before use; do not assume a portable unit is automatically suitable for enclosed work.<\/p>\n\n\n\n<style>\n\/* Style Isolation and Reset *\/\n.defu-v6-card-container * {\n    box-sizing: border-box;\n}\n\n\/* Main Container - Shorter Width, Taller Height *\/\n.defu-v6-card-container {\n    display: flex;\n    flex-wrap: wrap; \n    max-width: 750px; \n    margin: 35px auto; \n    background-color: #ffffff; \n    border-radius: 10px; \n    overflow: hidden; \n    box-shadow: 0 5px 25px rgba(0, 0, 0, 0.1); \n    font-family: Arial, sans-serif;\n    transition: all 0.3s ease;\n}\n\n.defu-v6-card-container:hover {\n    box-shadow: 0 10px 35px rgba(0, 0, 0, 0.15);\n    transform: translateY(-2px); \n}\n\n\/* Text Content Column (Left) *\/\n.defu-v6-card-text-column {\n    width: 55%; \n    padding: 40px 30px; \n    display: flex;\n    flex-direction: column;\n    justify-content: center;\n    background-color: #ffffff; \n    position: relative;\n}\n\n\/* Image Column (Right) *\/\n.defu-v6-card-image-column {\n    width: 45%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    padding: 20px;\n}\n\n\/* Product Title Styling *\/\n.defu-v6-card-title {\n    font-size: 28px; \n    font-weight: 700; \n    color: #0a1e3c; \n    margin-top: 0;\n    margin-bottom: 15px; \n    line-height: 1.2;\n}\n\n\/* Product Description *\/\n.defu-v6-card-description {\n    font-size: 16px; \n    line-height: 1.7; \n    color: #555555;\n    margin-bottom: 30px; \n}\n\n\/* CTA Button - \u6700\u7ec8\u4f18\u5316\u7248\u672c\uff1a\u5de6\u53f3\u8fb9\u8ddd\u8fdb\u4e00\u6b65\u7f29\u5c0f *\/\n.defu-v6-card-cta {\n    display: inline-block;\n    background: linear-gradient(135deg, #1a73e8 0%, #0c57c6 100%); \n    color: #ffffff !important;\n    \/* \u4fdd\u6301\u4e0a\u4e0b\u8fb9\u8ddd (15px) \u589e\u52a0\u9ad8\u5ea6\uff0c\u5c06\u5de6\u53f3\u8fb9\u8ddd\u7f29\u5c0f\u5230 18px *\/\n    padding: 15px 18px; \n    border-radius: 4px;\n    text-decoration: none;\n    font-weight: 700;\n    font-size: 16px; \n    border: none;\n    cursor: pointer;\n    text-align: center;\n    box-shadow: 0 4px 10px rgba(26, 115, 232, 0.3); \n    transition: all 0.3s ease;\n}\n\n.defu-v6-card-cta:hover {\n    background: linear-gradient(135deg, #0c57c6 0%, #0640a0 100%); \n    transform: translateY(-2px); \n    box-shadow: 0 6px 15px rgba(26, 115, 232, 0.45); \n}\n\n\/* Product Image - Clean Presentation *\/\n.defu-v6-card-image-wrapper {\n    width: 100%;\n    border-radius: 6px; \n    overflow: hidden;\n    transition: transform 0.3s ease;\n}\n\n.defu-v6-card-image-wrapper:hover {\n    transform: scale(1.03); \n}\n\n.defu-v6-card-image {\n    width: 100%;\n    height: auto;\n    display: block;\n    object-fit: cover;\n}\n\n\/* Responsive Design *\/\n@media (max-width: 768px) {\n    .defu-v6-card-container {\n        flex-direction: column; \n        margin: 20px 15px;\n        max-width: 100%;\n    }\n\n    .defu-v6-card-text-column,\n    .defu-v6-card-image-column {\n        width: 100%; \n    }\n\n    .defu-v6-card-text-column {\n        padding: 25px; \n        order: 2; \n        text-align: center; \n    }\n    \n    .defu-v6-card-image-column {\n        order: 1; \n        padding: 20px; \n    }\n\n    .defu-v6-card-title {\n        font-size: 24px;\n    }\n\n    .defu-v6-card-description {\n        font-size: 15px;\n    }\n    \n    .defu-v6-card-cta {\n        \/* \u79fb\u52a8\u7aef\u6062\u590d\u5bbd\u5ea6\uff0c\u4fdd\u8bc1\u53ef\u70b9\u51fb\u6027 *\/\n        width: 80%; \n        margin: 0 auto;\n        padding: 12px 18px; \/* \u79fb\u52a8\u7aef\u6309\u94ae\u4e0a\u4e0b\u8fb9\u8ddd\u7565\u5fae\u51cf\u5c0f *\/\n    }\n}\n<\/style>\n\n<div class=\"defu-v6-card-container\">\n    <div class=\"defu-v6-card-text-column\">\n        <p class=\"defu-v6-card-title\">Bomba de deshidrataci\u00f3n de lodos con cebado en seco asistido por vac\u00edo serie MP<\/p>\n        <p class=\"defu-v6-card-description\">\n            Soluci\u00f3n de alto rendimiento para las tareas de deshidrataci\u00f3n m\u00e1s exigentes en miner\u00eda, ofreciendo eficiencia y confiabilidad inigualables.\n        <\/p>\n        <a href=\"https:\/\/www.defucc.com\/es\/mine-dewatering-pump-manufacturer\/\" class=\"defu-v6-card-cta\" target=\"_blank\" rel=\"noopener noreferrer\">Explora las bombas de desag\u00fce de minas<\/a>\n    <\/div>\n\n    <div class=\"defu-v6-card-image-column\">\n        <a href=\"https:\/\/www.defucc.com\/es\/mine-dewatering-pump-manufacturer\/\" target=\"_blank\" rel=\"noopener noreferrer\" class=\"defu-v6-card-image-wrapper\">\n            <img decoding=\"async\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2025\/05\/MP-800x800.jpg\" alt=\"Bomba centr\u00edfuga qu\u00edmica DEFUC IHF\" class=\"defu-v6-card-image\">\n        <\/a>\n    <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Standby Capacity and Discharge Route<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Set standby capacity from the consequence of losing the duty pump, expected inflow variability, repair access, and the time needed to mobilize replacement equipment. Critical stages may need an installed standby pump, a quick-change connection, spare wear parts, or an independent backup arrangement; define which option is required in the project plan rather than leaving it to the shift crew.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Route discharge to an approved destination and confirm pipework can handle operating pressure, flow, and movement as excavation progresses. The U.S. Federal Highway Administration\u2019s Technical Manual for Design and Construction of Road Tunnels discusses groundwater-control methods and risks of unsuitable dewatering, including effects on nearby structures. Follow project-specific geotechnical advice and local discharge requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before handover, test the system at the planned operating point, inspect joints and restraints, verify fitted alarms or level controls, and confirm discharge stability. At each shift change, record sump levels, flow, pump status, and response actions to distinguish rising inflow from equipment deterioration and reduce repeated fault-finding.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusi\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A staged plan for tunnel dewatering should follow the water source, the advancing excavation, and the real duty at each lift point rather than rely on a single pump rating. Coordinating collection points, pump sizing, solids handling, equipment clearance, backup capacity, and discharge routing minimizes downtime and helps crews respond effectively to changing site conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Confirm each stage through inspection and commissioning records, and update the arrangement when the face advances or inflow patterns change. When reviewing the <a href=\"https:\/\/www.defucc.com\/es\/product-category\/centrifugal-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\">DEFU Centrifugal Pump range<\/a>, compare documented performance and service requirements against the same duty criteria to support reliable operation and contractor confidence.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. What is staged tunnel drainage?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Staged tunnel drainage directs water into designated collection points before transferring it through successive pumping stages as excavation progresses. The system layout should account for incoming water sources, elevation differences, workspace limitations, and the designated discharge location.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Why might a tunnel drainage pump lose flow?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common causes include a blocked strainer, sediment-filled sump, suction air leak, excessive head, worn components, or a restricted discharge line. Check the water level and suction path first, then compare the installed duty with the <a href=\"https:\/\/www.defucc.com\/es\/blog\/buying-guide\/dewatering-pump-curve\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/buying-guide\/dewatering-pump-curve\/\" rel=\"noreferrer noopener\">curva de bombeo<\/a> and document the corrective action.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. What should contractors check before installing drainage equipment underground?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Confirm the duty point, suction lift, pipe route, access for maintenance, power and ventilation requirements, discharge approval, and standby response. Test the installed system under expected conditions and record the results before relying on it for the next excavation stage.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.defucc.com\/es\/contact\/\" style=\"border-top-left-radius:82px;border-top-right-radius:82px;border-bottom-left-radius:82px;border-bottom-right-radius:82px;background-color:#c0c7cc\" target=\"_blank\" rel=\"noreferrer noopener\">Obtenga una cotizaci\u00f3n gratis<\/a><\/div>\n<\/div>\n\n\n\n<style>\n\/* ================================\n   Compact B2B Card \u2013 Isolated Style\n   Prefix: cldg-card-\n================================ *\/\n\n\/* Main Container *\/\n.cldg-card-container {\n    display: flex;\n    flex-wrap: wrap;\n    width: 100%;\n    max-width: 1000px;\n    margin: 16px auto;\n    border: 1px solid #e5e5e5;\n    border-radius: 6px;\n    overflow: hidden;\n    background-color: #ffffff;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.04);\n}\n\n\/* Text Column - \u5360 55% \u5bbd\u5ea6\uff0c\u5185\u8fb9\u8ddd\u8c03\u6574 *\/\n.cldg-card-text-column {\n    width: 55%;\n    padding: 24px;\n    box-sizing: border-box;\n    display: flex;\n    flex-direction: column;\n    justify-content: center;\n}\n\n\/* Image Column - \u5360 45% \u5bbd\u5ea6\uff0c\u76f8\u5bf9\u5b9a\u4f4d *\/\n.cldg-card-image-column {\n    width: 45%;\n    position: relative;\n    box-sizing: border-box;\n    overflow: hidden;\n    min-height: 220px; \/* \u4fdd\u8bc1\u6700\u5c0f\u9ad8\u5ea6 *\/\n}\n\n\/* Title - \u4ec5\u6807\u9898\u8bbe\u7f6e 20px \u548c\u52a0\u7c97 *\/\n.cldg-card-title {\n    font-size: 20px;\n    font-weight: 600;\n    color: #1a1a1a;\n    margin: 0 0 10px;\n    line-height: 1.35;\n}\n\n\/* Description *\/\n.cldg-card-description {\n    color: #555555;\n    margin-bottom: 18px;\n}\n\n\/* CTA Button \u2013 Light Gray *\/\n.cldg-card-cta {\n    display: inline-block;\n    max-width: 180px;\n    padding: 10px 18px;\n    background-color: #f2f2f2;\n    color: #333333;\n    text-decoration: none;\n    border-radius: 4px;\n    text-align: center;\n    border: 1px solid #d9d9d9;\n    transition: background-color 0.25s ease, border-color 0.25s ease;\n}\n\n.cldg-card-cta:hover {\n    background-color: #e6e6e6;\n    border-color: #cccccc;\n}\n\n\/* Image Position & Fit Adjustment - \u7edd\u5bf9\u5b9a\u4f4d\u6491\u6ee1\u53f3\u4fa7\uff0c\u9632\u6324\u538b *\/\n.cldg-card-image {\n    position: absolute;\n    top: 0;\n    left: 0;\n    width: 100%;\n    height: 100%;\n    display: block;\n    object-fit: cover;\n    object-position: center;\n}\n\n\/* Mobile responsive *\/\n@media (max-width: 768px) {\n    .cldg-card-container {\n        flex-direction: column;\n    }\n\n    .cldg-card-text-column,\n    .cldg-card-image-column {\n        width: 100%;\n    }\n\n    .cldg-card-text-column {\n        padding: 20px 16px;\n    }\n\n    .cldg-card-image-column {\n        position: relative;\n        height: 220px;\n    }\n}\n<\/style>\n\n<div class=\"cldg-card-container\">\n    <div class=\"cldg-card-text-column\">\n        <p class=\"cldg-card-title\">\u00a1Bienvenidos a nuestro blog!<br>Fabricante profesional de bombas de desag\u00fce<\/p>\n        <p class=\"cldg-card-description\">\n            Escrito por el equipo de Ingenier\u00eda y Soluciones de WENZHOU DEFU MACHINERY CO., LTD. Respaldados por 3 bases de fabricaci\u00f3n y m\u00e1s de 10 a\u00f1os de experiencia como fabricante l\u00edder de bombas de desag\u00fce, nuestro equipo se dedica a compartir informaci\u00f3n pr\u00e1ctica sobre bombas de desag\u00fce y soluciones de ingenier\u00eda para el manejo de fluidos en proyectos globales.\n        <\/p>\n        <a\n            href=\"https:\/\/www.defucc.com\/es\/contact\/\"\n            class=\"cldg-card-cta\"\n            target=\"_blank\"\n            rel=\"noopener noreferrer\"\n        >\n            Cont\u00e1ctanos \u2192\n        <\/a>\n    <\/div>\n\n    <div class=\"cldg-card-image-column\">\n        <img decoding=\"async\"\n            src=\"https:\/\/defucc.b-cdn.net\/wp-content\/uploads\/2025\/06\/2-1-1--768x534.jpg\"\n            alt=\"WENZHOU DEFU MACHINERY CO., LTD. - Fabricante de bombas de desag\u00fce\"\n            class=\"cldg-card-image\"\n        \/>\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Quick Answer For effective tunnel dewatering, the inflow must be collected from the source, transferred using planned lift stations, and<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":3174,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[58],"tags":[],"class_list":["post-3172","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mine-dewatering"],"_links":{"self":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/comments?post=3172"}],"version-history":[{"count":2,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3172\/revisions"}],"predecessor-version":[{"id":3249,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3172\/revisions\/3249"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/media\/3174"}],"wp:attachment":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/media?parent=3172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/categories?post=3172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/tags?post=3172"}],"curies":[{"name":"gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}