{"id":3185,"date":"2026-10-11T10:19:36","date_gmt":"2026-10-11T02:19:36","guid":{"rendered":"https:\/\/www.defucc.com\/?p=3185"},"modified":"2026-10-29T11:35:36","modified_gmt":"2026-10-29T03:35:36","slug":"sewage-pump-maintenance","status":"publish","type":"post","link":"https:\/\/www.defucc.com\/es\/blog\/sewage-pump\/sewage-pump-maintenance\/","title":{"rendered":"Sewage Pump Maintenance: A Preventive Checklist for Plant Operators"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Respuesta r\u00e1pida<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sewage pump maintenance is done through regular inspection, cleaning, testing, and servicing of the pumps in order to avoid clogging of the equipment, maintaining appropriate flows, preventing seal damage, and reducing unscheduled down time. An operator needs to monitor performance, follow the instructions provided in the manual of the equipment manufacturer, and note any faults before failure occurs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The intervals will be based on design of the equipment, hours of operation, amount of solids contained, and the consequences of outage. <a href=\"https:\/\/www.defucc.com\/es\/product\/tx-th-series-water-pump-self-priming-sewage-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\">The TX\/TH series self-priming sewage pump<\/a> will be evaluated in relation to the liquid, suction configuration, and operating duty rather than the name of the product. The information contained in DEFU can be used to establish what is required by the particular model.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Daily, Weekly, and Monthly Inspections<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A schedule of operation should conform to the conditions of the site and the instructions provided by the equipment manufacturer; it is not a replacement of the site plan. The daily schedule will include levels in the wet well, number of starts, hours of operation, alarms, discharge pressure or flow when applicable, and any unusual noise or vibration.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-1200x628.webp\" alt=\"Industrial pump installation with preventive maintenance schedule covering operating hours, alarms, flow, pressure, valves, controls, and performance checks.\" class=\"wp-image-3187\" srcset=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-1200x628.webp 1200w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-500x262.webp 500w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-300x157.webp 300w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-768x402.webp 768w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-18x9.webp 18w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-143x75.webp 143w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-484x253.webp 484w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image4-4-800x418.webp 800w\" sizes=\"auto, (max-width:767px) 484px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Weekly, inspect accessible pipework, valves, cable entries, control panels, and level sensors for damage or abnormal operation, and confirm that duty rotation and standby starts work as intended. Monthly, review performance trends and inspect accessible intake areas under approved safety procedures; remove rags, grease, grit, or debris when appropriate, and reflect the actual solids load and outage consequences in the documented <a href=\"https:\/\/www.defucc.com\/es\/blog\/sewage-pump-maintenance-checklist\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/sewage-pump-maintenance-checklist\/\" rel=\"noreferrer noopener\">sewage pump maintenance<\/a> routine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not enter a wet well unless the required confined-space assessment, entry permit, atmospheric testing, and rescue procedures are in place.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Clogging and Vibration<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.defucc.com\/es\/blog\/sewage-pump-clogging-causes\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/sewage-pump-clogging-causes\/\" rel=\"noreferrer noopener\">Clogging<\/a> may cause reduced flow, longer cycles, high-level alarms, or motor overloads. Before lifting a pump, check for rags and fibrous solids, blocked screens, closed valves, failed check valves, or downstream restrictions; resetting an overload without finding the cause can lead to repeat trips and motor damage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Compare vibration and noise with a known baseline, checking loose supports, pipe strain, obstructed impellers, bearing wear, coupling misalignment, and cavitation symptoms. For submersible pumps, inspect mounting and guide-rail seating during a planned lift with the unit safely isolated; after clearing a blockage, confirm that the pump restarts and restores expected flow or pressure, and if the fault returns, record the material removed and review screening, wet-well cleaning frequency, and pump suitability for the solids being handled.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Seals and Bearings<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Leaks near the shaft seal, moisture near the motor housing, or changes in seal-chamber condition may indicate wear, but inspection depends on pump design. Follow the manual for mechanical seals, packing, lubrication, and bearing temperature; do not add lubricant unless the specified type, quantity, and interval are clear.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Replacing a seal without investigating its failure can lead to repeat repairs; dry running, abrasive solids, misalignment, vibration, incorrect installation, or operation outside the specified duty can damage the replacement. Before restarting, check these surrounding conditions, verify alignment on coupled pumps after work on the motor, baseplate, or coupling, and confirm that piping loads do not pull the pump out of position; never open a sealed submersible motor or seal chamber unless an authorized technician and the model\u2019s service procedure permit it.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Spare Parts Inventory<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Stock parts according to failure impact, replacement frequency, supplier lead time, and standby capacity. Typical items may include approved seals, gaskets, bearings, impeller hardware, fuses, overload devices, and level-sensor components; the exact list must match the installed model and controls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use the operation and maintenance manual to confirm part numbers, dimensions, materials, and compatibility, then label critical stock by pump tag and set reorder points before supplies run out. Record each issue to distinguish routine consumption from repeated component failure, and define which repairs in-house staff can perform safely and which require specialist support, lifting equipment, electrical isolation, or a scheduled outage.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Maintenance Log Template<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A useful log links each observation to an action and result. Document the date and time, pump tag, operating hours, start cycles, available flow or pressure readings, wet-well level, alarms, unusual noise or vibration, leaks, maintenance performed, parts replaced, and responsible personnel.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"628\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-1200x628.webp\" alt=\"Pump maintenance checklist template showing operating readings, inspection findings, maintenance records, and return-to-service checks.\" class=\"wp-image-3186\" srcset=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-1200x628.webp 1200w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-500x262.webp 500w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-300x157.webp 300w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-768x402.webp 768w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-18x9.webp 18w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-143x75.webp 143w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-484x253.webp 484w, https:\/\/www.defucc.com\/wp-content\/uploads\/2026\/10\/image1-6-800x418.webp 800w\" sizes=\"auto, (max-width:767px) 484px, (max-width:1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Log field<\/th><th>What to record<\/th><\/tr><\/thead><tbody><tr><td>Operating condition<\/td><td>Wet-well level, flow or pressure, run hours, starts<\/td><\/tr><tr><td>Inspection finding<\/td><td>Noise, vibration, heat, leakage, clogging, alarm<\/td><\/tr><tr><td>Action taken<\/td><td>Cleaning, adjustment, repair, test, or no action<\/td><\/tr><tr><td>Parts and labour<\/td><td>Part number, quantity, technician, time spent<\/td><\/tr><tr><td>Return-to-service check<\/td><td>Restart, alarm reset, normal flow, follow-up required<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Compare like-for-like operating conditions over time; a steady decline in pressure at similar wet-well levels can indicate wear or restriction, while repeated alarms after cleaning suggest the cause remains unresolved. The Hydraulic Institute\u2019s pump maintenance guidance recommends routine monitoring of seals, bearings, vibration, noise, temperature, operating conditions, and maintenance records; adapt this guidance to the specific equipment manual and local requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusi\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A reliable sewage pump maintenance program combines routine checks, safe cleaning, condition-based troubleshooting, correct <a href=\"https:\/\/www.defucc.com\/es\/blog\/sewage-pump-spare-parts\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.defucc.com\/blog\/sewage-pump-spare-parts\/\" rel=\"noreferrer noopener\">spare parts<\/a>, and records that reveal changing performance. Investigate recurring faults instead of repeatedly resetting alarms or replacing components without finding the cause.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Close each job with a functional test: confirm valve positions, stable operation, expected discharge, and cleared alarms, then document follow-up work. For plants reviewing equipment options, the <a href=\"https:\/\/www.defucc.com\/es\/product-category\/centrifugal-pump\/\" target=\"_blank\" rel=\"noreferrer noopener\">DEFU centrifugal Pump<\/a> range can help frame pump-type comparisons; verify application fit and maintenance requirements before selection.<\/p>\n\n\n\n<style>\n\/* Style Isolation and Reset *\/\n.defu-v6-card-container * {\n    box-sizing: border-box;\n}\n\n\/* Main Container - Shorter Width, Taller Height *\/\n.defu-v6-card-container {\n    display: flex;\n    flex-wrap: wrap; \n    max-width: 750px; \n    margin: 35px auto; \n    background-color: #ffffff; \n    border-radius: 10px; \n    overflow: hidden; \n    box-shadow: 0 5px 25px rgba(0, 0, 0, 0.1); \n    font-family: Arial, sans-serif;\n    transition: all 0.3s ease;\n}\n\n.defu-v6-card-container:hover {\n    box-shadow: 0 10px 35px rgba(0, 0, 0, 0.15);\n    transform: translateY(-2px); \n}\n\n\/* Text Content Column (Left) *\/\n.defu-v6-card-text-column {\n    width: 55%; \n    padding: 40px 30px; \n    display: flex;\n    flex-direction: column;\n    justify-content: center;\n    background-color: #ffffff; \n    position: relative;\n}\n\n\/* Image Column (Right) *\/\n.defu-v6-card-image-column {\n    width: 45%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    padding: 20px;\n}\n\n\/* Product Title Styling *\/\n.defu-v6-card-title {\n    font-size: 28px; \n    font-weight: 700; \n    color: #0a1e3c; \n    margin-top: 0;\n    margin-bottom: 15px; \n    line-height: 1.2;\n}\n\n\/* Product Description *\/\n.defu-v6-card-description {\n    font-size: 16px; \n    line-height: 1.7; \n    color: #555555;\n    margin-bottom: 30px; \n}\n\n\/* CTA Button - \u6700\u7ec8\u4f18\u5316\u7248\u672c\uff1a\u5de6\u53f3\u8fb9\u8ddd\u8fdb\u4e00\u6b65\u7f29\u5c0f *\/\n.defu-v6-card-cta {\n    display: inline-block;\n    background: linear-gradient(135deg, #1a73e8 0%, #0c57c6 100%); \n    color: #ffffff !important;\n    \/* \u4fdd\u6301\u4e0a\u4e0b\u8fb9\u8ddd (15px) \u589e\u52a0\u9ad8\u5ea6\uff0c\u5c06\u5de6\u53f3\u8fb9\u8ddd\u7f29\u5c0f\u5230 18px *\/\n    padding: 15px 18px; \n    border-radius: 4px;\n    text-decoration: none;\n    font-weight: 700;\n    font-size: 16px; \n    border: none;\n    cursor: pointer;\n    text-align: center;\n    box-shadow: 0 4px 10px rgba(26, 115, 232, 0.3); \n    transition: all 0.3s ease;\n}\n\n.defu-v6-card-cta:hover {\n    background: linear-gradient(135deg, #0c57c6 0%, #0640a0 100%); \n    transform: translateY(-2px); \n    box-shadow: 0 6px 15px rgba(26, 115, 232, 0.45); \n}\n\n\/* Product Image - Clean Presentation *\/\n.defu-v6-card-image-wrapper {\n    width: 100%;\n    border-radius: 6px; \n    overflow: hidden;\n    transition: transform 0.3s ease;\n}\n\n.defu-v6-card-image-wrapper:hover {\n    transform: scale(1.03); \n}\n\n.defu-v6-card-image {\n    width: 100%;\n    height: auto;\n    display: block;\n    object-fit: cover;\n}\n\n\/* Responsive Design *\/\n@media (max-width: 768px) {\n    .defu-v6-card-container {\n        flex-direction: column; \n        margin: 20px 15px;\n        max-width: 100%;\n    }\n\n    .defu-v6-card-text-column,\n    .defu-v6-card-image-column {\n        width: 100%; \n    }\n\n    .defu-v6-card-text-column {\n        padding: 25px; \n        order: 2; \n        text-align: center; \n    }\n    \n    .defu-v6-card-image-column {\n        order: 1; \n        padding: 20px; \n    }\n\n    .defu-v6-card-title {\n        font-size: 24px;\n    }\n\n    .defu-v6-card-description {\n        font-size: 15px;\n    }\n    \n    .defu-v6-card-cta {\n        \/* \u79fb\u52a8\u7aef\u6062\u590d\u5bbd\u5ea6\uff0c\u4fdd\u8bc1\u53ef\u70b9\u51fb\u6027 *\/\n        width: 80%; \n        margin: 0 auto;\n        padding: 12px 18px; \/* \u79fb\u52a8\u7aef\u6309\u94ae\u4e0a\u4e0b\u8fb9\u8ddd\u7565\u5fae\u51cf\u5c0f *\/\n    }\n}\n<\/style>\n\n<div class=\"defu-v6-card-container\">\n    <div class=\"defu-v6-card-text-column\">\n        <p class=\"defu-v6-card-title\">Bomba de agua autocebante para aguas residuales serie TX\/TH\n<\/p>\n        <p class=\"defu-v6-card-description\">\n            Las bombas de aguas residuales autocebantes de la serie TX\/TH est\u00e1n dise\u00f1adas para eliminar impurezas de fibras ultra largas, s\u00f3lidos de 3 pulgadas confiables y manejo de l\u00edquidos claros.\n        <\/p>\n        <a href=\"https:\/\/www.defucc.com\/es\/product\/jt-ju-sellf-priming-sewage-pump\/\" class=\"defu-v6-card-cta\" target=\"_blank\" rel=\"noopener noreferrer\">Explora las bombas de desag\u00fce de minas<\/a>\n    <\/div>\n\n    <div class=\"defu-v6-card-image-column\">\n        <a href=\"https:\/\/www.defucc.com\/es\/product\/tx-th-series-water-pump-self-priming-sewage-pump\/\" target=\"_blank\" rel=\"noopener noreferrer\" class=\"defu-v6-card-image-wrapper\">\n            <img decoding=\"async\" src=\"https:\/\/www.defucc.com\/wp-content\/uploads\/2025\/05\/TX-TH-1.jpg\" alt=\"\" class=\"defu-v6-card-image\">\n        <\/a>\n    <\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Preguntas frecuentes<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. What should operators include in a routine sewage pump service?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A sewage pump service checklist should cover operating readings, alarms, noise and vibration, leaks, intake and discharge restrictions, controls, lubrication where applicable, and a documented return-to-service test. After installation or repair, confirm the pump is correctly secured, piping and valves are in the required positions, electrical protection is restored, and the unit runs at the expected flow or pressure; follow the model-specific manual for service tasks and intervals.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. What causes a sewage pump to clog repeatedly or trip frequently?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Common causes include ragging, blocked screens, restricted discharge, damaged impellers, unsuitable pump selection, and overloads reset without diagnosis. Check the full flow path and record the material removed before changing the maintenance interval.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. How often should wastewater pumps be inspected?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Wastewater pump maintenance frequency depends on run hours, solids, duty criticality, and the manufacturer\u2019s instructions. Start with daily operating checks and scheduled weekly or monthly inspections, then adjust the plan using recorded trends and recurring faults.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.defucc.com\/es\/contact\/\" style=\"border-top-left-radius:82px;border-top-right-radius:82px;border-bottom-left-radius:82px;border-bottom-right-radius:82px;background-color:#c0c7cc\" target=\"_blank\" rel=\"noreferrer noopener\">Obtenga una cotizaci\u00f3n gratis<\/a><\/div>\n<\/div>\n\n\n\n<style>\n\/* ================================\n   Compact B2B Card \u2013 Isolated Style\n   Prefix: cldg-card-\n================================ *\/\n\n\/* Main Container *\/\n.cldg-card-container {\n    display: flex;\n    flex-wrap: wrap;\n    width: 100%;\n    max-width: 1000px;\n    margin: 16px auto;\n    border: 1px solid #e5e5e5;\n    border-radius: 6px;\n    overflow: hidden;\n    background-color: #ffffff;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.04);\n}\n\n\/* Text Column - \u5360 55% \u5bbd\u5ea6\uff0c\u5185\u8fb9\u8ddd\u8c03\u6574 *\/\n.cldg-card-text-column {\n    width: 55%;\n    padding: 24px;\n    box-sizing: border-box;\n    display: flex;\n    flex-direction: column;\n    justify-content: center;\n}\n\n\/* Image Column - \u5360 45% \u5bbd\u5ea6\uff0c\u76f8\u5bf9\u5b9a\u4f4d *\/\n.cldg-card-image-column {\n    width: 45%;\n    position: relative;\n    box-sizing: border-box;\n    overflow: hidden;\n    min-height: 220px; \/* \u4fdd\u8bc1\u6700\u5c0f\u9ad8\u5ea6 *\/\n}\n\n\/* Title - \u4ec5\u6807\u9898\u8bbe\u7f6e 20px \u548c\u52a0\u7c97 *\/\n.cldg-card-title {\n    font-size: 20px;\n    font-weight: 600;\n    color: #1a1a1a;\n    margin: 0 0 10px;\n    line-height: 1.35;\n}\n\n\/* Description *\/\n.cldg-card-description {\n    color: #555555;\n    margin-bottom: 18px;\n}\n\n\/* CTA Button \u2013 Light Gray *\/\n.cldg-card-cta {\n    display: inline-block;\n    max-width: 180px;\n    padding: 10px 18px;\n    background-color: #f2f2f2;\n    color: #333333;\n    text-decoration: none;\n    border-radius: 4px;\n    text-align: center;\n    border: 1px solid #d9d9d9;\n    transition: background-color 0.25s ease, border-color 0.25s ease;\n}\n\n.cldg-card-cta:hover {\n    background-color: #e6e6e6;\n    border-color: #cccccc;\n}\n\n\/* Image Position & Fit Adjustment - \u7edd\u5bf9\u5b9a\u4f4d\u6491\u6ee1\u53f3\u4fa7\uff0c\u9632\u6324\u538b *\/\n.cldg-card-image {\n    position: absolute;\n    top: 0;\n    left: 0;\n    width: 100%;\n    height: 100%;\n    display: block;\n    object-fit: cover;\n    object-position: center;\n}\n\n\/* Mobile responsive *\/\n@media (max-width: 768px) {\n    .cldg-card-container {\n        flex-direction: column;\n    }\n\n    .cldg-card-text-column,\n    .cldg-card-image-column {\n        width: 100%;\n    }\n\n    .cldg-card-text-column {\n        padding: 20px 16px;\n    }\n\n    .cldg-card-image-column {\n        position: relative;\n        height: 220px;\n    }\n}\n<\/style>\n\n<div class=\"cldg-card-container\">\n    <div class=\"cldg-card-text-column\">\n        <p class=\"cldg-card-title\">\u00a1Bienvenidos a nuestro blog!<br>Fabricante profesional de bombas de desag\u00fce<\/p>\n        <p class=\"cldg-card-description\">\n            Escrito por el equipo de Ingenier\u00eda y Soluciones de WENZHOU DEFU MACHINERY CO., LTD. Respaldados por 3 bases de fabricaci\u00f3n y m\u00e1s de 10 a\u00f1os de experiencia como fabricante l\u00edder de bombas de desag\u00fce, nuestro equipo se dedica a compartir informaci\u00f3n pr\u00e1ctica sobre bombas de desag\u00fce y soluciones de ingenier\u00eda para el manejo de fluidos en proyectos globales.\n        <\/p>\n        <a\n            href=\"https:\/\/www.defucc.com\/es\/contact\/\"\n            class=\"cldg-card-cta\"\n            target=\"_blank\"\n            rel=\"noopener noreferrer\"\n        >\n            Cont\u00e1ctanos \u2192\n        <\/a>\n    <\/div>\n\n    <div class=\"cldg-card-image-column\">\n        <img decoding=\"async\"\n            src=\"https:\/\/defucc.b-cdn.net\/wp-content\/uploads\/2025\/06\/2-1-1--768x534.jpg\"\n            alt=\"WENZHOU DEFU MACHINERY CO., LTD. - Fabricante de bombas de desag\u00fce\"\n            class=\"cldg-card-image\"\n        \/>\n    <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Quick Answer Sewage pump maintenance is done through regular inspection, cleaning, testing, and servicing of the pumps in order to<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":3188,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[63],"tags":[],"class_list":["post-3185","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sewage-pump"],"_links":{"self":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/comments?post=3185"}],"version-history":[{"count":3,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3185\/revisions"}],"predecessor-version":[{"id":3241,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/posts\/3185\/revisions\/3241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/media\/3188"}],"wp:attachment":[{"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/media?parent=3185"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/categories?post=3185"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.defucc.com\/es\/wp-json\/wp\/v2\/tags?post=3185"}],"curies":[{"name":"gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}